Availability: | |
---|---|
Quantity: | |
As the most effective Cryolipolysis Fat Freezing Body Slimming Machine, it has been widely welcomed in the medical and beauty fields
This machine comes with 4 handpieces in different treatment sizes. Their numbers are #100, #150, #200, #300. Of course, we can also supply this machine with different handpiece combinations, like 2 x #150 and 2 x #200 or otherwise according to your needs.
This machine can drive 2 handpieces simultaneously. There are other similar machines from other suppliers which can drive 4 handpieces at the same time. Why does Brolaser still insist on driving two handles at the same time? After all, driving four handles at the same time is a simple change. The reason for doing this is that Brolaser's premise for all considerations is to achieve the best treatment effect. According to a large number of experiments and enough customer usage, it is enough to prove that driving two handles at the same time can make the instrument play the best energy output to achieve the best effect.
Its operation is very simple:
Clip the heart rate monitor on the index finger of one of the patient's hands, and hold the handheld emergency stop controller with the other hand.
Adjust the parameters on the screen
Spread the antifreeze film corresponding to the size of the handle flat on the treatment area.
Place the handle steadily on the treatment area, press the handle button, and the handle will start to suck.
When the suction feels that it has reached the range you can bear, the operator will press the handle button again to maintain the suction. If you press the button for the third time, the suction will be released.
If you do not press the button for the third time, the treatment will continue. When the set time is reached (defaut 45 minutes), the suction will automatically be released and the treatment will end.
How Cryolipolysis works?
It's based on that fat cells are more sensitive to cold than surrounding tissue. When fat cells are exposed to a specific low temperature caused by this cryolipolysis, a process called apoptosis (programmed cell death) is triggered.
The cold causes the fat cells to crystallize and break down. Gradually, the body’s natural immune system recognizes these damaged fat cells as waste and eliminates them through phagocytosis by the time. The lymphatic system also transports the broken down fat cells away from the treatment area.
This results in a reduction in the number and size of fat cells in the targeted area, resulting in a slimming effect.
The skin is protected from frostbite due to the antifreeze film.
The effects of cryolipolysis surgery are usually visible 2 to 4 months after treatment and continue to improve for up to 6 months. Although these effects are not as quick as those achieved through liposuction surgery, patients who undergo cryolipolysis surgery can avoid the pain, risks, and long recovery times associated with these more invasive procedures. Most patients who undergo cryolipolysis surgery are very satisfied with the surgical results and can enjoy a natural and slim appearance. Although there are currently no long-term studies, the effects of cryolipolysis surgery are expected to be as long-lasting as the fat reduction effects achieved through traditional liposuction surgery.
Specifications
Input | 110V/60Hz, 220V/50Hz |
Power | 800VA |
Heat | 37℃~45℃ |
Cryo | 5℃~-10℃ |
Suck power | 10~80Kpa |
Light | Red (630nm), Green(570nm) 50mWX4 |
Cooling liquid | Pure water or special coolant |
Volume | 44x48.5x98cm |
Fuse | T3. 15AL250V |
Ambient temperature | 5℃~40℃ |
Relative humidity | <=80% |
Atmospheric pressure | 86Kpa~106Kpa |
As the most effective Cryolipolysis Fat Freezing Body Slimming Machine, it has been widely welcomed in the medical and beauty fields
This machine comes with 4 handpieces in different treatment sizes. Their numbers are #100, #150, #200, #300. Of course, we can also supply this machine with different handpiece combinations, like 2 x #150 and 2 x #200 or otherwise according to your needs.
This machine can drive 2 handpieces simultaneously. There are other similar machines from other suppliers which can drive 4 handpieces at the same time. Why does Brolaser still insist on driving two handles at the same time? After all, driving four handles at the same time is a simple change. The reason for doing this is that Brolaser's premise for all considerations is to achieve the best treatment effect. According to a large number of experiments and enough customer usage, it is enough to prove that driving two handles at the same time can make the instrument play the best energy output to achieve the best effect.
Its operation is very simple:
Clip the heart rate monitor on the index finger of one of the patient's hands, and hold the handheld emergency stop controller with the other hand.
Adjust the parameters on the screen
Spread the antifreeze film corresponding to the size of the handle flat on the treatment area.
Place the handle steadily on the treatment area, press the handle button, and the handle will start to suck.
When the suction feels that it has reached the range you can bear, the operator will press the handle button again to maintain the suction. If you press the button for the third time, the suction will be released.
If you do not press the button for the third time, the treatment will continue. When the set time is reached (defaut 45 minutes), the suction will automatically be released and the treatment will end.
How Cryolipolysis works?
It's based on that fat cells are more sensitive to cold than surrounding tissue. When fat cells are exposed to a specific low temperature caused by this cryolipolysis, a process called apoptosis (programmed cell death) is triggered.
The cold causes the fat cells to crystallize and break down. Gradually, the body’s natural immune system recognizes these damaged fat cells as waste and eliminates them through phagocytosis by the time. The lymphatic system also transports the broken down fat cells away from the treatment area.
This results in a reduction in the number and size of fat cells in the targeted area, resulting in a slimming effect.
The skin is protected from frostbite due to the antifreeze film.
The effects of cryolipolysis surgery are usually visible 2 to 4 months after treatment and continue to improve for up to 6 months. Although these effects are not as quick as those achieved through liposuction surgery, patients who undergo cryolipolysis surgery can avoid the pain, risks, and long recovery times associated with these more invasive procedures. Most patients who undergo cryolipolysis surgery are very satisfied with the surgical results and can enjoy a natural and slim appearance. Although there are currently no long-term studies, the effects of cryolipolysis surgery are expected to be as long-lasting as the fat reduction effects achieved through traditional liposuction surgery.
Specifications
Input | 110V/60Hz, 220V/50Hz |
Power | 800VA |
Heat | 37℃~45℃ |
Cryo | 5℃~-10℃ |
Suck power | 10~80Kpa |
Light | Red (630nm), Green(570nm) 50mWX4 |
Cooling liquid | Pure water or special coolant |
Volume | 44x48.5x98cm |
Fuse | T3. 15AL250V |
Ambient temperature | 5℃~40℃ |
Relative humidity | <=80% |
Atmospheric pressure | 86Kpa~106Kpa |